What was found
* RH SLAT TRACK 2-1, TRACK IS CHAFED. FLAGGED (C-CHECK RO 9/21/2021) BLENDED OUT CHAFE ON R/H SLAT TRACK 2-1REF. CRJ-700 SRM 51-12-00-001-001-A01. RECIEVED REO 670-57-42-1164 REV -- DATED 2021-08-24 FROM ENGINEERING. COMPLIED WITH REO 670-57-42-1164 REV -- DATED 2021-08-24 STEP 1. ENSURED BLENDOUTS WERE PERFORMED PER SRM. STEP 2.NDT. STEP 3. APPLIED AEROSHELL #33. STEP 4. / SLAT TRACK WITH REO 670-57-42-1164. / COMPLIED WITH STEP 6 OF REO 670-57-42-1164 REV -- DATED 2021-08-24 PRE CRJ700 AMM TASK . COMPLIED WITH REO 670-57-42-1164REV -- DATED 2021-08-24 STEP 7. ENSURED SLAT RIGGING. / REQUIREMENTS WERE MET REF. CRJ-700 AMM 27-81-00-820-801-A02 51-900-1002-SKY