What was found
RH FLOOR SILL FS280 TO FS319, SPLICE ANGLE STGR 17R, PART# SH670-31580-1 IS CORRODED. (C-CHECK RO 9/21/2021) CORROSION IS 100% THROUGH SPLICE ANGLE STGR 17R ON RH FLOOR SILL FS280 TO FS319 AND IS OUT OF LIMITS REF CRJ700 SRM 53-00-00-101-001-A01. REMOVED BAD ANGLE REF CRJ700 SRM 51-42-06-001-001-A01 AND REF CRJ700 SRM 51-42-10-001-001-A01. ORDERED AND RECEIVED REPLACEMENT SPLICE ANGLE PART# SH670-31580-1. ORDERED AND RECEIVED REPLACEMENT FASTENERS AND INSTALLED ANGLE ON FLOOR SILL WITH REPLACEMENT FASTENERS DRW. SH670-32170 REV V, REF CRJ700 SRM 51-42-13-001-001-A01 AND REF CRJ700 SRM 51-42-06-001-001-A01. COMPLETED SKYCARD 51-900-1002-SKY.