What was found
*FRAME, FS295.00, CORRODED STGR 24L -STGR25R. (MARKED) (C-CHECK RO 9/27/2021) - REMOVED CORROSION ON FRAME FS295.00 BETWEEN STGR 23LH AND STGR 25RH. CRJ-700 SRM 51-21-06-001-001-A01 ORIGINAL MATERIAL THICKNESS IS .050PER CRJ 700 SRM 53-21-06-001-002-A01 , LOWEST READING AFTER BLENDOUT WAS .037 FOUND TO BE OUT OF LIMITS PER CRJ 700 SRM 53-21-06-101-002-A01. CUT OUT CORRODED SECTION AND INSTALLED REPAIR PARTS AT FS295 BETWEEN STR25L AND 25R IAW CRJ700 SRM 53-00-06-201-006-A01. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY