What was found
RBL 9.00, FLOOR BEAM FLANGE ON INBOARD SIDE OF BEAM IS CORRODED AT APPROX. (28 EA) LOCATIONS AROUND NUTPLATE HOLES AND WHERE FLANGE MEETS SEAT TRACK BETWEEN F.S. 409.00+128 AND F.S. 559.00. (C-CHECK RO 10/07/2021) REPAIRED RBL 9.00, FLOOR BEAM FLANGE ON INBOARD SIDE OF BEAM IS CORRODED AT APPROX. (28 EA) LOCATIONS AROUND NUTPLATE HOLES AND WHERE FLANGE MEETS SEAT TRACK BETWEEN F.S. 409.00+128 AND F.S. 559.00.IAW MHIRJ REO 601R-53-41-2966 REV -- DATED 2021-09-20, MHIRJ REO 601R-53-41-2967 REV -- DATED 2021-09-18 AND SKY CARD 51-900-1003-SKY NO WEIGHT CHANGE, FORM 337 IS ATTACHED REF ATTACHED CONTINUATION CARD FOR DETAILS OF WORK PERFORMED