What was found
* THE PRESSURE FLOOR SUPPORT STRUCTURE'S FS 484 INTERCOSTAL BETWEEN LBL 27 AND LBL 36 HAS A CRACKED INBOARD CLIP THAT ATTACHES TO LBL 27. (MARKED WITH ORANGE FLAG TAPE) (C-CHECK RO 10/8/2021) REMOVED AND REPLACED INBD CLIP ON FS 484 INTERCOSTAL LBL 27 REF CRJ 200 SRM 51-42-21 AND REO 601R-53-41-059 REV -C DATE 2020-03-11 (FOR FASTENERS SUBSTITUTION) / COMPLIED WITH SKY CARD 51-900-1003-SKY