What was found
* THE PRESSURE FLOOR SUPPORT STRUCTURE'S FS 484 INTERCOSTAL BETWEEN LBL 9 AND LBL 18 HAS A CRACKED INBOARD CLIP THAT ATTACHES TO LBL 9. (MARKED WITH ORANGE FLAG TAPE) (C-CHECK RO 10/8/2021) REMOVED AND REPLACED INBD CLIP FOR PRESSURE FLOOR SUPPORT STRUCTURE FS 484 INTERCOSTAL BETEEEN LBL9 AND LBL18 REF DWG 601R31171 REV E, AND REF CRJ 200 SRM 51-42-06 / -ACOMPLISHED SKY CARD 51-900-1003-SKY