What was found
RH SLA TRACK 1-2 HAS EVIDENCE OF CORROSION ON I/B SIDE, FRETTING CORROSION ON BOTTOM SURFACE 2 EA PLACES, FRETTING CORROSION ON TOP SURFACE 2 EA PLACES, PROTECTIVE COATING MISSING ON I/B AND O/B SIDES (C-CHECK RO 11/04/2021) BLENDED FRETTING CORROSION AREAS ON RH SLAT TRACK 1-2 REF-CRJ-900 REO 690-57-42-842 REV-- DATE 2021-10-06. REF, CRJ900 SRM 51-12-00-001-001-A01 REV.38 DATE JUL/25/2020 / COMPLIED WITH TASK 51-900-1002-SKY