As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RBL 9 FLOOR BEAM BETWEEN FS 559 AND FS 559+64 CORRODED OUT OF LIMITS, FROM CAMP 23329338 JOB97404121 OP#293 (C-CHECK- RO 11/11/21) REMOVED AND REPLACED RBL9 FLOOR BEAM AT F/S 559 TO 559+64 IAW CRJ 200 SRM 51-42-06, 51-42-36 AND REO 601R-53-51-599 REV -- DATED 2021-09-03. COMPLETED TASK CARD 51-900-1003-SKY AND ATTACHED COMPLETED FORM 337. NO WEIGHT CHANGE NOTED.