What was found
EVIDENCE OF CORROSION ON PLATE BRACKET AT INTERCOSTAL BETWEEN STGR 22L AND STGR 23L, BETWEEN FS533.00 AND FS534.00 INTERNAL SURROUND STRUCTURE OF FORWARD BAGGAGE BAY DOOR. (C-CHECK RO 11-24-21) BLENDED CORROSION ON PLATE BRACKET BETWEEN STGR 22L AND STGR23L FROM FS533.00 TO FS534.00 OF INTERNAL SURROUND STRUCTURE ON FWD BAG BAY DOOR REF. CRJ-700 SRM, 51-21-06-001-001-A01. FOUND TO BE OUT OF LIMITS, REPLACED WITH NEW PLATE BRACKET REF. DWG SH670-33600 REV Y, REF CRJ-700 SRM, 51-42-21-001-001-A01 AND REF. CRJ-700 SRM, 51-42-22-001-001-A01. TASK CARD 51-900-1002-SKY COMPLIED WITH.