What was found
EVIDENCE OF CORROSION FOUND JUST RIGHT OF STRINGER 27 ON FLANGE OF FRAME AT STATION 310 (C-CHECK RO 11-27-21) REMOVED & REPLACED WITH NEW FRAME EVIDENCE OF CORROSION FOUND JUST RIGHT OF STRINGER 27 ON FLANGE OF FRAME AT STATION 310 REF CRJ-700 SRM 53-00-06-201-006-A01.COMPLIED WITH 51-900-1002-SKY,PRESSURE LEAK CHECK GOOD.