What was found
THE GALLEY #1 HAS A CORRODED DOUBLER LOCATED BEHIND THE FLOOR MOUNT FITTING AT THE INBD EDGE/AFT LOCATION. (C-CHECK RO 11-27-21) REPLACED THE CORRODED DOUBLER LOCATED BEHIND THE FLOOR MOUNT FITTING AT THE INBD EDGE/AFT LOCATION WITH A SERVICEABLE DOUBLER (P/N=9335071-1) REFERENCING CRJ 700 SRM 51-41-02-001-001-A01 AND CRJ 700 SRM 51-41-04-01-001-A01, TORQUE WRENCH USED: TUC#8613, CAL DUE 31-OCT-21.