What was found
ADM# N471CA-7479 DAMAGE IS LOCATED BETWEEN FS 672.00 AND FS 682.00 BETWEEN STRINGERS STGR 1R AND STGR 2R DENT IS 1" LONG FWS TO AFT AND 1/4" WIDE SIDE TO SIDE PLOT, MAP, AND EVALUATE DAMAGE IF WITHIN ACCEPTABLE LIMITS OR REWORKED, ELIMINATE EVIDENCE USING STANDARD ACFT PRACTICES. (C CHECK RO 12/28/2021) REPAIRED DENT IAW CRJ 200 SRM 53-00-31 REPAIR NO. 3. 337 AND MAJOR REPAIR TASK CARD 51-900-1003-SKY COMPLETED AND ATTACHED. WEIGHT CHANGE OF +1.13LBS. SEE CONTINUATION CARD FOR DETAILS OF WORK PERFORMED.