What was found
FLOOR SUPPORT STRUCTURE AT FS280 AND BETWEEN RBL9 AND LBL9 UNDER PANEL 221ALF, ANGLE CORRODED. (C-CHECK RO 1/5/2022) REMOVED AND REPLACED FLOOR SUPPORT STRUCTURE ANGLE AT FS280 BETWEEN RBL9 AND LBL9 UNDER PANEL 221ALF IAW CRJ 200 SRM 51-40-11, 51-42-06, 51-42-21, 51-25-00 AND SKY CARD 51-900-1003-SKY NO WEIGHT CHANGE, FORM 337 IS ATTACHED REF CONTINUATION CARD FOR DETAILS OF WORK PERFORMED