What was found
L/H HORZONAL STAB TIP PANEL HAS MISLOCATED NUTPLATE ON INBOARD EDGE, THIRD NUTPLATE FWD OF TRAILING EDGE OF STAB TIP. (C-CHECK RO 1/5/2022) REMOVED AND REPLACED RIB AND SPLICE WITH NEW FABRICATED PN: 600-23079-S0101 RIB AND PN: 600-23037-22 SPLICE IAW REO 601R-55-11-707 REV: -- DATE: 2021-12-18 AND EO 600-23026 SNIEO ID: S01 REF: BOMBARDIER DWG 600-23-037 REV: L FOR FASTENER CALL OUT SEE CONTINUATION FOR DETAILS.