What was found
CORROSION, AFT WET AREA, ON RH SHEAR PANEL BETWEEN FRAMES 86 AND 87 AROUND GALLEY MOUNT POINTS AND ALONG FORWARD EDGE (C CHECK RO 1/14/2022) / REMOVED AND REPLACED RH SHEAR PANEL BETWEEN FRAMES 86 AND 87 REF EMB SRM 51-40-08 SEE CONTINUATION CARD FOR WORK ACCOMPLISHED