What was found
R/H LONERON PRESSURE FLOOR ANGLE FS409+128 TO FS559 CORROSION AS MARKED (C CHECK RO 1/20/22) CORROSION DAMAGE ON R/H LONGERON PRESSURE FLOOR ANGLE FS409+128 TO FS559 REMOVED, ORIGNAL THICKNESS 0.080", DAMAGE REMOVED WAS 0.003", REMAINING THICKNESS 0.077". DAMAGE FOUND TO BE WITHIN LIMITS IAW REO 601R-53-41-666 REV-C DATE: 2012-11-06. RESTORED SURFACE FINISH IAW CRJ200 SRM 51-21-16 TRESHOLD REPEAT INSPECTION AT 8260 FLIGHT CYCLES. CURRENT FLIGHT CYCLES 36,894 NEXT INSPECTION DUE AT 45,154 FLIGHTT CYCLES. IAW: REO601R-53-41-666 REV-C- 2021-11-06, SHEET #2. PERFORMED PRESSURE CHECK IAW CRJ200 AMM 21-31-00 REV 64 SEPT10/2021. / CALIBRATED TOOLS USED: / OLYMPUS 650 EPOC AV8959 CAL DUE OCT2021 / OLUMPUS 600 NORTEC AV8958 CAL DUE OCT2021