What was found
FS 693 LOWER CAP ANGLE HAS 2 AREAS OF DAMAGE ON RADIUS OF THE AFT, TOP "Z" ANGLE SECTION CAUSED FROM TRAPPED FASTENERS COMMON TO BULKHEAD BEAMS, FS 693 BULKHEAD WEB AND CAP ANGLE. (FILED CLOSED) REMOVED AND INSTALLED SERVICEABLE FS 693 LOWER BULKHEAD CAP ANGLE IAW CRJ-700 SRM 51-42-21-001-001-A01,51-42-06-001-001-A01. COMPLETED AND ATTACHED TASK CARD 51-900-1002-SKY AND M-337. NO WEIGHT CHANGE.