What was found
COMPLY WITH SCHEDULED MAINTENANCE CODE: RA55489-601R-57-31-1334-N929SW MXCODEID50310-PR - THE LHS WINGLET STRUCTURE HAS DISCREPANT FASTENER HOLES. PERFORMED TEMP REPAIR IN REF TO REO 601R-57-31-1334 REV B, DTD 12/25/2019. PERM REPAIR DUE WITHIN 5000 FLT HRS OF THIS REPAIR INCORPORATION AT 47745.10 TAT, PART NUMBER: - , SERIAL NUMBER: 7703, POSITION: (C CHECK RO 02-12-2022) PERFORMED PERMANENT REPAIR TO THE LHS WINGLET STRUCTURE. REF REO 601R-57-31-1385 REV -- DATE 2022-02-08, CRJ200 SRM 51-42-06, CRJ200 SRM 51-42-21, CRJ200 SRM 51-42-13 DWG 600-15108 REV -C, DWG 600-15110 REV -E., AND DWG 600-15102 REV. C, COMPLIED WITH 51-900-1003-SKY