What was found
LBL18 FLOOR BEAM SUPPORT FITTING AT FS460.0 HAS A SUSPECTED CRACK ON THE UPPER AND LOWER CORNERS (MARKED) (C CHECK RO 02-12-2022) REMOVED AND INSTALLED NEW FLOOR BEAM SUPPORT FITTING FS460.0 LBL18 REF DWG 601R31118 REV L AND CRJ 200 SRM 51-42-21. COMPLIED WITH 51-900-1003-SKY. ALL CHECKS GOOD