As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
*CORROSION ON PAX DOOR INTERCOSTAL MID DD6 (C CHECK RO 2/17/2022) CORROSION FOUND OUT OF LIMITS. INSTALLED NEW REPLACEMENT INTERCOSTAL (P/N 601R318057-1) ONTO PAX DOOR BETWEEN FS320.00 AND FS338.00 USING NEW HARDWARE. REF BOMBARDIER DWG# 601R31702 REV -N AND CRJ700 SRM'S 51-42-06-001-001 A01, 51-42-21-001-001 A01. COMPLIED WITH TASK CARD 51-900-1002-SKY. LEAK GOOD