What was found
CORROSION FOUND ON STRINGER 26R BETWEEN FS280.00 AND FS333.00. (C CHECK RO 2/17/2022) REMOVED AND REPLACED STGR26R BETWEEN FS280.00 - FS333.00 REF CRJ700 SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01 AND DWG SH670-31630 REV K. LEAK CHECK OF REPAIR AREA GOOD REF CRJ700 AMM 21-31-00-910-801-A01. COMPLIED WITH TASK CARD 51-900-1002-SKY. SEE CONTINUE CARD FOR WORK PERFORMED.