As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSERT FOUND TO BE DAMAGED REQUIRES REPLACEMENT IN WARDROBE FRONT BOTTOM CORNER PLATE (C CHECK RO 3/11/2022) INSERT FOUND TO SERVICABLE AND FLOOR FITTING AND DOUBLER WERE FOUND CORRODED OUT OF LIMITS AND WERE REPLACED WITH NEW PARTS IAW C&D ZODIAC CMM 25-20-52 PAGE. 7001 ASSEMBLY PAR. 2 - A. (2) STEPS (CF) - (CG) FIG.16 SEE CONTINUATION FOR DETAILS