As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
9 INCH CREASE FOUND ON FUSELAGE SKIN AT F.S 319-333 BETWEEN STRINGER 25L-26L (C CHECK RO 02-03-22) REPAIR TO FUSELAGE SKIN BETWEEN FS310.00 TO FS349.00 AND STR 24 & 27 LHS . COMPLIED WITH REO 670-53-21-2218 REV -- DATED 2022-01-17. COMPLIED WITH TASK CARD 51-900-1002-SKY. LEAK CHECK GOOD. SEE CONTINUATION CARD FOR DETAILS.