What was found
CORROSION ON AFT WET AREA CENTER SHEAR PANEL BETWEEN FR87-88 AS MARKED. (C CHECK RO 2/20/2022) / REMOVED AND REPLACED CENTER SHEAR PANEL BETWEEN FR87-88 REF SRM 51-40-08. SEE CONTINUATION CARD FOR WORK PERFORMED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON AFT WET AREA CENTER SHEAR PANEL BETWEEN FR87-88 AS MARKED. (C CHECK RO 2/20/2022) / REMOVED AND REPLACED CENTER SHEAR PANEL BETWEEN FR87-88 REF SRM 51-40-08. SEE CONTINUATION CARD FOR WORK PERFORMED.