What was found
*SERVICE DOOR SILL AREA €“ ANGLE ATTACHED TO LOWER SILL HAS CORROSION BETWEEN FS319 AND FS347 (MARKED (C CHECK RO 02/25/2022) REMOVED AND REPLACED NEW ANGLE MOUNTING P/N 31996-1 ON SERVICE DOOR SILL BETWEEEN FS 319.00 - FS 347.00 REF CRJ700 SRM 51-42-06-001-001-A01 REVISION 38, DATED JULY 25/2020. DWG SH670-31950, REV Y. COMPLIED WITH TASK CARD 51-900-1002-SKY AND FORM M-337. SEE CONTINUE CARD FOR MORE DETAILS