What was found
RH PRESSURE FLOOR SILL ANGLE FROM FS 449.85 TO FS 484.00 IS CORRODED IN MULTIPLE LOCATIONS. (C CHECK RO 3/11/2022) REPAIRED CORROSION DAMAGE AT FS 449,461 AND 473 IAW REO 601R-53-41-666 REV C DATED 2012-11-06 AND INSTALLED ALTERNATE FASTENERS AT INACCESSABLE LOCATIONS IAW REO 601R-53-41-3016 REV -- DATED 2022-02-05. NO CHANGE TO WEIGHT AND BALANCE, M-337 AND SKYCARD 51-900-1003-SKY ATTACHED.NO CHANGE TO WEIGHT AND BALANCE. REFERENCE CONTINUATION CARD FOR WORK PERFORMED.