What was found
LH FLOOR SUPPORT ANGLE FOUND TO BE CRACKED AT LBL 9.0 JUST FWD FS 280. (C-CHECK RO 3/11/2022) DISCREPANCY LOCATION IS LBL 12 THERE IS NO STRUCTURE LOCATED AT LBL9 JUST FWD OF FS280 / INSTALLED NEW LH FLOOR SUPPORT ANGLE LBL 12. REF CRJ 700 CRJ700 SRM 51-42-06-001-001-A01, CRJ700 SRM 53-11-43-201-003-A01 DWG #CC670-33052 REV F, COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY.