What was found
*CORROSION ON RH FLOOR SILL BETWEEN FS 559.00 €“ APPROX 559.00+80 (C-CHECK RO 3/14/2022) REMOVED CORROSION FROM RH FLOOR SILL BETWEEN FS559.00-559.00+80 IAW CRJ200 SRM 51-21-06-00 .INTERCOSTAL AT 559-559+16 FOUND TO BE OUT OF LIMITS REF CRJ 200 SRM 53-00-00. REOMVED AND REPLACED INTERCOSTAL REF MHIRJ REO 601R-53-51-614 REV -- 2022-02-21 COMPLIED WITH TASK CARD 51-900-1003-SKY. / 559+16-559+80 RIGHT FLOOR SILL FOUND TO BE IN LIMITS REF REO 601R-53-00-526 REV-- DATED 22-MAY-2013. COMPLIED WITH ALL STEPS OF MHIRJ REO 601R-53-51-614 REV -- 2022-02-21 AND REO 601R-53-00-526 REV-- DATED 22-MAY-2013. SEE CONTINUATION CARD FOR DETAILS.