What was found
CORROSION AT MOUNT HOLES ON R/H SHEAR PANEL LOCATED AT FRAME 87/88. (C-CHECK RO 03-19-2022) REMOVED AND REPLACED R/H SHEAR PANEL LOCATED AT FRAME 87/88 REF EMB SRM 51-40-08 AND RESTORED SURFACE PROTECTION REF SRM 51-23-06
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AT MOUNT HOLES ON R/H SHEAR PANEL LOCATED AT FRAME 87/88. (C-CHECK RO 03-19-2022) REMOVED AND REPLACED R/H SHEAR PANEL LOCATED AT FRAME 87/88 REF EMB SRM 51-40-08 AND RESTORED SURFACE PROTECTION REF SRM 51-23-06