What was found
RH ELEVATOR OUTBOARD PCU FAILS BACKLASH FUNCTIONAL TEST. (C-CHECK RO 03-19-2022) REPLACED HARDWARE TO THE R/H ELEVATOR O/B PCU TO ELEVATOR ATTACH POINT ON RACK. REF. E175 AMM 27-32-01. REACOMPLISHED RH ELEVATOR BACKLASH FUNCTIONAL TEST FOR RH ELEVATOR OUTBOARD PCU REF. EMB 175 AMM 27-30-00-720-801-A. FUNCTIONAL TEST GOOD. DIAL INDICATORTC2-8876 DUE: 10-6-22 FORCE GAUGE: TC2-7347 DUE: 2-1-23. SEE CONTINUE CARD FOR WORK ACOMPLISHED.