What was found
MAIN AVIONICS BAY FS333.00 FRAME CORRODED BETWEEN STR 26L AND STR 25R (C-CHECK RO 4/25/2022) REMOVED AND INSTALLED NEW FS333.00 FROM STR 21L TO STR 20R, SPLICE REPAIR AND REINFORCING ANGLE SPLICE REF CRJ900 SRM 53-00-06-201-001-A03, CRJ900 SRM 51-42-06-001-001-A01 AND DWG: SH670-32420 REV-E. ENSURED MHIRJ REO 690-53-21-1496 REV-A DATED 2022-03-21 DISPOSITION IS COMPLIED WITH. COMPLIED WITH TASK CARD 51-900-1002-SKY. LEAK CHECK GOOD. SEE CONTINUE CARD FOR DETAILS.