What was found
CORROSION, AFT WET AREA ON END OF LH INBOARD SEAT TRACK BETWEEN FRAME 84 AND 85. (C-CHECK RO 5/4/2022) BLENDED AND EVALUATED CORROSION, AFT WET AREA ON END OF LH INBOARD SEAT TRACK BETWEEN FR 84 AND 85. MEASUREMENTS 0.39"L X 0.33"W X 0.19"H. NOMINAL THICKNESS 0.363", REMAINING 0.173". ITEM IS OUT OF LIMITS PER REF 53-23-10AD04. REPAIRED IN ACCORDANCE TO ETD2022-170-013405.