What was found
STR24R HAS CORROSION BETWEEN FS927 AND FS977. (C CHECK RO 5/23/22) REMOVED CORROSION FROM STGR 24R BETWEEN FS.927 & FS.977 REF. CRJ900 SRM TASK 51-21-06-001-001-A01. FUSELAGE SKIN STGR 24R P/N SH690-37065-4 WITH CORROSION DAMAGED ATTACHED FLANGE BETWEEN FS.927 & FS.977 AND WITH NO DAMAGE ALLOWED BETWEEN FS.969 & FS.977 IS OUT OF LIMIT PER CRJ900 SRM TASK 53-51-03-101-003-A04 FIG. 53-51-03-995-816 SHEET 2. REMOVED AND INSTALLED NEW STRINGER 24R BETWEEN FS847 AND FS977 AND ALL ATTACHING STRUCTURE (CLEATS, INTERCOSTALS AND ANGLES) EXCEPT STRINGER SPLICE BETWEEN FS847+32 AND FS847+48 AND STRINGER CLIP AT FS847. REF. CRJ900 SRM 51-42-21-001-001-A01, SRM 51-42-06-001-001-A01, DWG # SH690-37060 REV. AC AND REO 690-53-51-336 REV. -- DATED 2022-04-19. PRESSURE LEAK CHECK OF REPAIR AREA CHECKED GOOD, NO LEAKS NOTED REF. CRJ-900 AMM, 21-31-00-910-801-A02 / . COMPLIED WITH 51-900-1002-SKY