What was found
CORROSION ON CLIP AT STGR 24R, FS1015. (C CHECK RO 5/23/22) REMOVED CORROSION. REF: CRJ-900 SRM 51-21-06-001-001-A01 ORIGINAL THICKNESS IS 0.050" WITH REMAINING 0.043" AND MATERIAL LOSS 0.007" WITH MAX. PERMISSIBLE 0.005", THEREFORE FOUND TO BE OUT OF LIMITS. REF: CRJ-900 SRM 53-61-03-001-003-A02 AND CRJ-900 SRM 53-00-00-101-001-A01. TOOL USED TO MEASURE: MICROMETER TUC 6516 DUE 31-JAN-23 INSTALLED NEW CLIP AT STRINGER 24R FS1015 REF CRJ900 SRM 51-42-21-001-001-A01 AND DWG MM670-35227 REV-A. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY. SEE CONTINUATION CARD FOR DETAILS.