What was found
STRINGER JOINT SPLICE AT 24L CORRODED AT FS333. (C CHECK RO 5/23/22) REPLACED STRINGER JOINT SPLICE AT 24L AT FS333 REF DWG SH670-32420 REV. E, CRJ900 SRM 51-42-06-001-001-A01. COMPLIED WITH 51-900-1002-SKY. LEAK CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER JOINT SPLICE AT 24L CORRODED AT FS333. (C CHECK RO 5/23/22) REPLACED STRINGER JOINT SPLICE AT 24L AT FS333 REF DWG SH670-32420 REV. E, CRJ900 SRM 51-42-06-001-001-A01. COMPLIED WITH 51-900-1002-SKY. LEAK CHECK GOOD.