Service difficulty report · None · Emb EMB110*

Difficulty date
June 18, 2022
Submitted
June 23, 2022
Operation
Air carrier
Aircraft
N243SY
Make and model
Emb EMB110*
Aircraft serial
17000592
Aircraft time
14,188 hours, 10,266 cycles
Part
None
Condition
Odor
Stage of operation
CL
How discovered
O
Nature of condition
P
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

STRONG BURNING SMELL IN FWD CABIN AND FLIGHT DECK WHILE CLIMBING THROUGH FL250 WITH ANTI ICE ON. / SMELLED ELECTRICAL IN NATURE, DISSIPATED SHORTLY AFTER. (FLIGHT 4076 - FILED CLOSED) UPON ARRIVAL, INTERROGATED CMC AND FOUND FAULT CODE 30114010AM2. T/S R/H WING SLAT 4 O/B TEMP SENSOR IN REF TO ERJ 175 FIM TASK 30-11-00-810-807-A AND PERFORMED BLOCK 1, SUB TASK 810-048-A, OPS CHECK FOR WING A-I BACKWALL TEMP SENSOR PASSED. NO DEFECTS NOTED, NO SIGNS OF ABNORMAL SMELL. PERFORMED ABNORMAL/SMOKE/ODOR SMELL CHECK IN REF TO ERJ 175 FIM TASK 21-20-00-810-801-A, BLOCK DIAGRAMS 1-10 (PAGES 4-14); NO ABNORMAL/SMOKE/ODOR SMELL NOTED UPON COMPLYING W/ BLOCK DIAGRAMS 1-10,PAGES 4-14. CONSIDERED TRANSITORY CONDITION OF AIR CONDITION PACKS PER SUBTASK 813-019-A. PERFORMED DETAILED INSPECTION OF THE LEFT/RIGHT PACKS AND RECIRCULATION FANS FOR ANY ABNORMALTIES THAT COULD LEAD TO A BAD SMELL WITH NO SIGNS OF DAMAGE. VERFIED NO CB TRIPPED AND PERFORMED GVI OF FWD/AFT/MIDDLE AVONICS BAY AND FWD/AFT CARGO FOR ANY SIGNS OF ABNORMAL DAMAGE OR SMOKE/ODOR SMELL NOTED. PERFORMED OPS CHECK OF WING THERMAL A-I SYSTEM IN REF TO ERJ 175 AMM 30-11-00. OPS CHECK GOOD, NO MESSAGES NOTED ON EICAS. COULD NOT DUPLICATE ABNOR