What was found
FWD EQUIPMENT BAY - R/H DOOR - AFT LATCH - EQUIPMENT BAY FLOOR SILL CRACKED @ UPPER RADIUS OF AFT LATCH RECEPTICAL (C-CHECK RO 7/8/2022) SEE ATTACHED CERTIFICATE FOR MHIRJ GEOMETRIC CONTOUR ANALYSIS APPROVAL. / COMPLIED WITH SKYWEST TASKCARD 51-900-1002-SKY. / REMOVED AND INSTALLED NEW REPLACEMENT RH DOOR LANDING (P/N CC670-33151-6) REF BOMBARDIER DWG# CC670-33040 REV G AND CRJ700 SRM 51-42-06-001-001 A01, 51-42-13-001-001 A01 REV 38 DATED JUL 25/2020, REO 670-53-11-1804 REV -- DATED 2022-05-23