What was found
L/H FLOOR SILL IS CORRODED BETWEEN F.S. 424 TO F.S. 439. (C-CHECK RO 7/26/2022) REMOVED CORROSION AND FOUND TO BE WITHIN LIMITS , COMPLIED WITH REO 601R-53-41-666 REV-C DATED 2012-11-06 ON L/H FLOOR SILL .FORM 337 AND MAJOR REPAIR TASK CARD 51-900-1003-SKY COMPLETED AND ATTACHED. NO WEIGHT CHANGE, SEE ATTACHED CONTINUATION CARD FOR DETAILS OF WORK PERFORMED.