As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TOP OF FLOOR BEAM CORRODED IN MULTIPLE LOCATIONS BETWEEN FS 409.+32 AND FS 409+95 AT LBL 9. (C-CHECK RO 7/26/2022) REPLACED FLOOR BEAM CAP IAW CRJ 200 REO 601R-53-31-1233 REV-- DATED: 2024-06-24. FORM 337 AND MAJOR REPAIR TASKCARD 51-900-1003-SKY COMPLETED AND ATTACHED. NO WEIGHT CHANGE, SEE CONTINUATION CARD FOR DETAILS OF WORK PERFORMED.