As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TOP OF FLOOR BEAM CORRODED IN MULTIPLE LOCATIONS BETWEEN FS 409.00 AND FS 409+95 AT RBL 9. (C-CHECK RO 7/26/2022) REPLACED FLOOR BEAM CAP IAW CRJ 200 REO 601R-53-31-1233 REV-- DATED: 2024-06-24. FORM 337 AND MAJOR REPAIR TASKCARD 51-900-1003-SKY COMPLETED AND ATTACHED. NO WEIGHT CHANGE, SEE CONTINUATION CARD FOR DETAILS OF WORK PERFORMED.