What was found
COCKPIT FLOOR STRUCTURE CENTER CROSS BEAM AT FRAME 11 CORRODED AS MARKED / (C-CHECK RO 8/29/2022) BLENDED COCKPIT FLOOR STRUCTURE CROSS BEAM AT FR 11 2EA LOCATIONS. DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-10-10/AD02. ASSET#:TC2-8911 CAL DUE:11-9-22. CUTOUT DAMAGE AND INSTALLED REPAIR AND DOUBLER IAW ETD2022-170-021794 REV A. RESTORED SURFACE PROTECTION IAW SRM 51-23-04,51-23-05,51-23-06. REFERENCE CARD FOR WORK PERFORMED.