What was found
REF EAML 983241 FOR RAMP DAMAGE TO FWD FUSELAGE SKIN BETWEEN FRAMES 21-22 AND STRINGERS 16L-17L, FOUND SKIN PUNCTURE / DENT TO BE DETERMINE OUT OF LIMITS PER ERJ 175 SRM 53-10-01 MEASURING DEPTH .1614" (4.10MM), LENGTH 1.403", WIDTH 0.967". (FILED CLOSED) THIS DISCREPANCY WAS TRANSFERRED TO CAMP ITEM 25424770 WITH THE FOLLOWING CORRECTIVE ACTION: "SEE CP 25425724 FOR REPAIR COMPLIANCE AND M-337"