What was found
R/H I/B FLAP TRACK 1A HAS THICKNESS REDUCTION OF .029" WITH A GOUGE IN RADIUS OF TRACK. (C-CHECK RO 1/3/2023) .REMOVED AND REPLACED RH I/B FLAP TRACK 1A REF EMB 175 AMM 57-54-25.ASSET# TC2-552 CAL DUE 4/7/23.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R/H I/B FLAP TRACK 1A HAS THICKNESS REDUCTION OF .029" WITH A GOUGE IN RADIUS OF TRACK. (C-CHECK RO 1/3/2023) .REMOVED AND REPLACED RH I/B FLAP TRACK 1A REF EMB 175 AMM 57-54-25.ASSET# TC2-552 CAL DUE 4/7/23.