What was found
L/H I/B FLAP TRACK 1A HAS THICKNESS REDUCTION OF .030". LENGTH OF DAMAGE IS .6". REMOVED AND REPLACED LH I/B FLAP TRACK 1A REF EMB 175 AMM 57-54-25.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L/H I/B FLAP TRACK 1A HAS THICKNESS REDUCTION OF .030". LENGTH OF DAMAGE IS .6". REMOVED AND REPLACED LH I/B FLAP TRACK 1A REF EMB 175 AMM 57-54-25.