What was found
INTERNAL STRUCTURE OF AVIONICS BAY DOOR SURROUND INNER DOOR LANDING HAS FRETTING AROUND MOST OF ITS PERIMETER (C-CHECK RO 4/17/2023) BLEND IS WITHIN LIMITS REF GREO 690-53-21-032 REV. -- DATED 2008/03/07, ORIGINAL MATERIAL T=0.120" REMAINING 0.115" REMOVED 0.005" MAX REMOVAL ALLOWED 0.040", NO PRESSURE LEAK CHECK REQUIRED WHEN BLEND DEPTH IS LESS THAN 0.015" COMPLIED WITH ALL STEPS OF GREO 690-53-21-032 REV. -- DATED 2008/03/07COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY. COMPLIED WITH SKYWEST FORM M-337.BLEND ONLY NO WEIGHT CHANGE