What was found
FOUND CORROSION AROUND NUTPLATES ON THE RH FLOOR SILL IN THE CABIN INTERIOR. APPROXIMATELY 1" AFT OF FS 529.00 (C-CHECK RO 2/23/2024) REPAIRED CORROSION DAMAGE AROUND NUTPLATES ON THE RH FLOOR SILL IN THE CABIN INTERIOR APPROXIMATELY 1" AFT OF FS 529.00 PER REO 601R-53-41-666 REV "-C" DATED 2012-11-06. PERFORMED UT REMAINING THICKNESS MEASUREMENT WITH REFERENCE TO NDTM PART 4 51-00-001 AND FOUND TO BE WITHIN LIMITS PER REO 601R-53-41-666 REV "-C". PERFORMED EDDY CURRENT INSPECT PER NDTM 51-20-06 AND ENSURED REWORKED AREAS TO BE CRACK FREE. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLIED WITH M-337. COMPLETED CORROSION FINDINGS REPORT.