As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EVIDENCE OF CORROSION FOUND ON L/H FLOOR SILL AT AFT CARGO DOOR CUT-OUT MULTIPLE LOCATIONS (C-CHECK RO 3/19/2024) REPLACED CARGO DOOR FLOOR SILL PER BOMBARDIER DRAWING 601R35011 (REV R) -AND- CRJ200SRM 51-42-06 (REVISION 39 DATED MAR 10/2021) -AND- CRJ200SRM 51-42-22 (REVISION 39 DATED MAR 10/2021).COMPLETED SKYWEST TASK CARD 51-900-1003-SKY AND SKYWEST FORM M-337.