What was found
FORWARD BAGGAGE BAY DOOR EXTERNAL SURROUND STRUCTURE HAS 3 GOUGES AS MARKED (C-CHECK RO 4/24/2024) REPLACED AFT SEAL STRIKER WHERE 3 GOUGES WHERE LOCATED ON FORWARD BAGGAGE BAY DOOR EXTERNAL SURROUND STRUCTURE REF. CRJ700 SRM 51-42-06-001-001-A01 REV. 38 JUL 25/2020 AND BOMBARDIER DWG SH670-33750 REV AA. FWD SEAL STRIKER IS WITHIN LIMITS REF CRJ700 SRM 53-31-23-101-001-A01. AND CRJ700 SRM 53-00-00-101-001-A01. LEAK CHECK GOOD SKYWEST TASK CARD 51-900-1002-SKY COMPLIED WITH.