What was found
PAX DOOR AFT DD5 INTERCOSTAL HAS EXFOLIATED CORROSION ON TWO ELEMENT REQUIRE REPLACEMENT JOB # HN00144727 (C-CHECK RO 4/26/2024) INSTALLED NEW PAX DOOR AFT DD5 INTERCOSTAL IAW CRJ 700 SRM 51-42-06-001-001-A01 AND DWG 601R31702 REV. N. COMPLIED WITH TASK CARD 51-900-1002-SKY. NO LEAKS NOTED.