RH SLAT PANEL #3 NOSE SKIN HAS CHAFES IN TWO SPOTS AS MARKED. (C-CHECK RO 5/14/2024) BLENDED OUT THE CHAFES ON RH WING #3 SLAT LEADING EDGE NOSE SKIN. BLEND DIMENSIONS AS FOLLOWS; D= .010", L= 1.747", W= 1.498", NOMINAL THICKNESS= .087", MAXIMUM ALLOWABLE DEPTH= .017", REMAINING THICKNESS= .077". DAMAGE IS ALLOWED RO REMAIN AS IS PERMANENTLY WITH NO ADDOTIONAL REPAIR PER ETD2024-170-012219 THE REWORKED AREAS MUST BE DETAILED VISUAL INSPECTED EVERY 24 MONTHS FOR CORROSION AS OF MAY 10TH, 2024. IF ANY CORROSION IS FOUND IT MUST BE REPORTED FOR RE-ASSESSMENT.